点击查看大图RQDG-200
臭氧在大气体中的含量虽然很少,但却是橡胶龟裂的主要因素。本公司生产的耐臭氧老化试验机可用于人工模拟或强化大气中的臭氧条件,以研究臭氧对橡胶的作用规律,快速鉴定的评价橡胶抗臭氧老化性能与抗臭氧剂防护效能。
- ✓原厂校准证书
- ✓12 个月质保
- ✓全国安装调试
- ✓支持非标定制
产品介绍
臭氧在大气体中的含量虽然很少,但却是橡胶龟裂的主要因素。本公司生产的耐臭氧老化试验机可用于人工模拟或强化大气中的臭氧条件,以研究臭氧对橡胶的作用规律,快速鉴定的评价橡胶抗臭氧老化性能与抗臭氧剂防护效能。
产品特点
- 结构
- 材料: a、试验内体:不锈钢板; b、机体外壳:烤漆板; c、保温:PU绝缘
- O3发生器:紫外线方式
- 转动系数:2转/分钟 恒速电机
- O3检测系统:电脑Windows软件显示(光化学传感器式)
- 控制系统:全电脑Windows温控及时控三、主要参数
- O3浓度控制:0-200(500)pphm(或者按要求定制)
- 温度:0-50℃
- 时间:任意值
- 显示:老化试验过程数码摄像,照片打印。
从物理效应到测量结果,讲清设备的工作原理。压头物镜试样光源数据处理原理要点模腔上下模以设定频率(如 1.7Hz)与振幅(±0.5°)相对摆动,胶料在腔内承受剪切变形,反作用转矩由扭矩传感器采集随交联密度上升转矩增大,曲线给出 ML(最低转矩)、MH(最高转矩)、ts1/ts2(焦烧时间)、t10/t50/t90(硫化时间)常见问题How do I choose the right configuration?Send us the specimen material, dimensions and applicable standard; an engineer will propose the model and fixturing, and provide a written selection proposal.Are the published specifications final?They are reference values for the standard configuration. Final configuration, price and lead time are stated in the formal quotation.Do you support sample testing?Yes. Send samples for measurement; we provide a test report together with the recommended configuration.相关机型RQDGCXRQWSKRQDG-200RQMN-2000获取报价 →参数对比 →咨询工程师 →
技术规格
选型指南
- 按工况对应推荐系列,再与工程师确认具体配置。工况推荐系列选型理由常规配方与质控选标准型(±0.5°、1.7Hz)以上参数仅供参考,最终配置、价格与交期以正式报价单为准。研究型选可变频率/应变机型以上参数仅供参考,最终配置、价格与交期以正式报价单为准。需与门尼黏度联测选带门尼模块以上参数仅供参考,最终配置、价格与交期以正式报价单为准。高温快检选 200℃ 以上高温型。以上参数仅供参考,最终配置、价格与交期以正式报价单为准。常见问题How do I choose the right configuration?Send us the specimen material, dimensions and applicable standard
- an engineer will propose the model and fixturing, and provide a written selection proposal.Are the published specifications final?They are reference values for the standard configuration. Final configuration, price and lead time are stated in the formal quotation.Do you support sample testing?Yes. Send samples for measurement
- we provide a test report together with the recommended configuration.相关机型RQDGCXRQWSKRQDG-200RQMN-2000获取报价 →参数对比 →咨询工程师 →
检测与验收
- 取样、制样、检测、复核与验收判据。标准作业流程用标准胶(如 NR 标准胶)校验转矩示值与温度模腔温度均匀性需满足 ±0.3℃,试验前必须做空白(无料)基线校准验收判据用标准块间接检定:工作面均布不少于 5 点,示值误差与重复性需满足相应检定规程。注意事项班前用标准块校验,保持压头与试样表面清洁,测量系统定期用标准刻线尺校准。常见问题How do I choose the right configuration?Send us the specimen material, dimensions and applicable standard
- an engineer will propose the model and fixturing, and provide a written selection proposal.Are the published specifications final?They are reference values for the standard configuration. Final configuration, price and lead time are stated in the formal quotation.Do you support sample testing?Yes. Send samples for measurement
- we provide a test report together with the recommended configuration.相关机型RQDGCXRQWSKRQDG-200RQMN-2000获取报价 →参数对比 →咨询工程师 →
常见问题
RQDG-200 的报价与交期是多久?
RQDG-200 可以先寄样实测吗?
出厂随机附带哪些资料?
能否按工件定制夹具或扩展量程?
售后响应与培训如何安排?
交付与服务
- 主机一台(全新原装)
- 标准附件与工具组
- 说明书、合格证、装箱单
- 出厂校准证书
- 标准出口木箱包装
- 全国物流 3–7 天送达
- 工程师上门安装调试
- 现场操作与保养培训
- 整机质保 12 个月
- 故障 48 小时内响应
- 每年一次免费巡检
- CNAS 第三方校准代办
把工件与检测要求发给我们
工程师 1 个工作日内回复选型方案、配置清单与报价。